Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

HARMAN KARDON DPR1005 Repair Manual

$7.99

HARMAN KARDON DPR1005 - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Carl Conti - 08/03/2006 5 of 5 Stars!
Thanks for manual for Luxman M02. I'll recomend this site to my friends for sure! Keep on the good work!
John Craig - 07/31/2006 5 of 5 Stars!
Very nice site and the manual is great. A life-saver. Thank you so much!
Mark Tarkett -  5 of 5 Stars!
Excellent service, good price, products are excellent. Will do business with this vendor again.
Paul Brady - 01/03/2007 5 of 5 Stars!
Talk about a lifesaver!!!!!!!!!!!! This schematic will also work for the Radio Shack DX-392. This is the full blown service manual complete with alignment instructions, schematics, and parts lists.
Aaron Lawrence - 01/02/2008 4 of 5 Stars!
Contains mechanism diagrams, parts lists and schematics for all worldwide versions of DC-X88Z. Also includes remote schematic etc. A few non-essential pages are missing such as specifications. Includes the mechanical and electronic calibration instructions for the tape decks.

Customers who bought this product also purchased
HARMAN KARDON 1001-A Service Manual
HARMAN KARDON 1001-A Service Manual
HARMAN KARDON 1001 Service Manual
HARMAN KARDON 1001 Service Manual
HARMAN KARDON CA240 Service Manual
HARMAN KARDON CA240 Service Manual
HARMAN KARDON 1000.4GTI Owner's Manual
HARMAN KARDON 1000.4GTI Owner's Manual
HARMAN KARDON 175A Service Manual
HARMAN KARDON 175A Service Manual
HARMAN KARDON AVI100 Service Manual
HARMAN KARDON AVI100 Service Manual

Click to see text excerpt from the manual
DPR1005/DPR2005 harman/kardon
5.3ACTIVATING THE AMPLIFIER
CONSUMERThe GR70 does not maintain control register settings when power is off. After reset the GR70 amplifier is in a passive state, all
registers are in their reset state, which results in the outputs being muted.
The following procedure activates the amplifier:
? SET MD0 and MD1
? To activate the output stages, SET the EAPD bit in the ConfF register 05H.
? The MPC bit in ConfA register 00H must be CLEARED for normal operation of the amplifier.
? Configure individual volume controls, mutes, and master volume registers as needed.
? MD0 and MD1 must remain SET for normal amplifier operation.
5.4POWER DOWN AND POWER OFF
The PowerDown state is the condition where the supplies are at their nominal level, but the amplifier is inactive due to the assertion
or either /RESET or /PWRDWN. Chapters 13.3 through 13.5 describe PowerDown operation. To avoid output pops, the /RESET
input should not be used to transition from the active state to the PowerDown state.
PowerOff is the condition where one or more power supply is off. When transitioning from PowerOff to the condition where all
power supplies are at their nominal level, /RESET should be active. This insures that the amplifier initializes properly with no output
pops. When transitioning from active operation to PowerOff, put it in the PowerDown state or clear the EAPD bit in the ConfF
register 05H. From the PowerDown state (or EAPD low) the power supplies can be turned off without speaker output pops.
5.5ENABLING ZONE 2
When enabling or disabling the second zone, the following procedure is used:
? SET MD1 and MD0.
? SET master mute bit, MMute, in Mmute register 06H.
? Power down the amplifier output stages, CLEAR EAPD bit in ComfF register 05H.
? CLEAR MD1 and SET Z2_EN.
2
? If the zone 2 input is analog, enable zone 2 analog input, SET Z2_AD_EN. The input format must also be configured for IS with
a 48kHz sample rate.
? Configure the digital input format and sample rate using ConfA register 00h and ConfB register 01H. Access to any other registers will
result in undesired operation. The Zone 2 outputs, CH5_OUT and CH6_OUT, are now assigned to input channels Five and Six.
? Program all parameters for zone 2 - EQ, volume, etc.
?SET MD1
? Restore the amplifier output stages: SET EAPD bit in ConfF register 05H and CLEAR the MMute bit in Mmute register 06H.
The amplifier is now ready for operation in the dual zone configuration.
5.6SAMPLE RATE CHANGE WITH ZONE 2 ENABLED
The sample rate of the primary channels may be modified without disturbing the operation of Zone 2. This will be required when
switching between 44.1-48kHz, 96kHz, or 192kHz. Follow this procedure:
? Mute channels 1 through 4 and 7: SET bits C1M through C4M and C7M in Channel Mute register 08H.
?CLEAR MD0.
? Power down the primary amplifier output stages: CLEAR EAPD bit in ConfF register 05H.
? Configure the primary sample rate and digital input format using ConfA register 00h and ConfB register 01H. Access to any other
registers will result in undesired operation.
?SET MD0.
? Restore the amplifier output stages: SET EAPD bit in ConfF register 05H and CLEAR bits C1M through C4M, CM7 in Channel Mute
register 08H.
The amplifier is now ready for operation.
5.7HEADPHONE OPERATION WITH ZONE 2 ENABLED
The amplifier digital outputs may be used to drive headphones via an external DAC. The speaker outputs of the primary output
channels can be muted for headphone only operation without disturbing the operation of Zone 2. The procedure is:
?CLEAR MD0.
? Power down the primary amplifier output stages, CLEAR EAPD bit in ConfF register 05H.
?SET MD0.
To restore the primary output channels:
?CLEAR MDO
?SET EAPD bit in ConfF register 05H.
GR70 Data Sheet Aug 26, 2003 v1.82

49
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-XS30B
RD-XS30B
Quick Start

$4.99
Current Parse Time: 0.083 s with 42 queries. Queries took 0.008359